Thursday, 12 August 2010
100811 Site Visit
Otway ceilings- CVA to schedule making good notes following site visit
Hearth to be maintained- timber floor to terminate to perimeter at same level
Roof awaiting insulation
Valley boards installed
Awaiting insulation- valley board installed
brickwork high level GL E 1st floor
Window to former basement- CVA detail update to follow
Sleeper walls- HUT COI to follow
Brick pattern amended to classroom
Insulation overcut to CL.ED.00.02
Concrete spalling to majority of ring beam high level- HUT to forward proposals for remedial works for comment
Ring beam GL C-D/4 to be removed/ recast
Spalling high level ring beam- alternative location
GL C-D/4- under demolition/ prior to recast
chimney base- RJC/HUT to forward remedial proposals for comment
All builderswork to be in accordance with drawings- HUT confirm
CL.EW.00.15- lintol required high level internally
NEE to confirm proposals for comment to high level trays classroom corridor GFL
Door frames on site
Assembly screed to plant too high at door threshold
water internally to WC areas assembly hall- temporary drainage to be rectified
M&E works in progress- lobby to assembly main hall
RWP high level assembly
Water internally- temporary drainage to be rectified
GL Q/14- taping to be addressed to corner
taping around windposts high level assembly hall
Blanking panel- SecCo detail required- no brick ties
Colour mortar- gaps GL N/20
Wind post to be painted behind hit and miss brick panel
Grey perp vents required where not adjacent to heritage red header
Water ingress adjacent toilets Assembly GFL
Frieze pattern high level GL 20
GL 18 heritage red brickwork underway
Awaiting Ibstock specials courses 71,72,73
Lintol- HUT to confirm as AI 210
Ditto
Brick patterning from Ingrave Road